Public Thermostat – (Tamperproof)
Tamperproof public thermostat designed for secure and controlled temperature management in shared spaces.
Durable and reliable, it prevents unauthorised adjustments while ensuring comfort.
Easy to install and energy-efficient, ideal for schools, offices, and public buildings.
External pilot wire for night reduction, equipped with a switch to select comfort, reduction or clock mode.
Possibility to regulate either the floor or room temperature, or combined (in this case, the floor sensor is used as temperature limiter)Relay output, to be connected directly to actuators (see connecting drawing on the installation sheet) or to our Modular
connecting system. (In this case please refer to the connecting box datasheet) - Manuals
-
Specifications
- Measured temperature precision 0.1°C
Operating temperature 0°C – 50°C
Setting temperature range 5°C – 30°C
Floor limiting temperature range 10°C – 40°C
Regulation characteristics Proportional band 10min for 2°C or Static - differential 0.5°C
Electrical Protection Class II – IP30
Power Supply 230 VAC +/- 10%
Output Relay output 230VAC,200W max
External Floor sensor NTC (10K Ohms) 3m
- Measured temperature precision 0.1°C
Tamperproof Public Thermostat
£29.99 inc.VAT

-
Description
Public Thermostat – (Tamperproof)
Tamperproof public thermostat designed for secure and controlled temperature management in shared spaces.
Durable and reliable, it prevents unauthorised adjustments while ensuring comfort.
Easy to install and energy-efficient, ideal for schools, offices, and public buildings.
External pilot wire for night reduction, equipped with a switch to select comfort, reduction or clock mode.
Possibility to regulate either the floor or room temperature, or combined (in this case, the floor sensor is used as temperature limiter)Relay output, to be connected directly to actuators (see connecting drawing on the installation sheet) or to our Modular
connecting system. (In this case please refer to the connecting box datasheet) - Manuals
-
Specifications
- Measured temperature precision 0.1°C
Operating temperature 0°C – 50°C
Setting temperature range 5°C – 30°C
Floor limiting temperature range 10°C – 40°C
Regulation characteristics Proportional band 10min for 2°C or Static - differential 0.5°C
Electrical Protection Class II – IP30
Power Supply 230 VAC +/- 10%
Output Relay output 230VAC,200W max
External Floor sensor NTC (10K Ohms) 3m
- Measured temperature precision 0.1°C